• Powerful 12 amp motor, 20-foot cord length
  • 11-1/4-inch nozzle width
  • Dual scrub brushes that wash and wipe away spots and stains
  • Two tank system to keep cleaning solution and dirty water separate
  • 133-ounce clean water capacity, 128-ounce dirty water capacity
  • Fingertip solution control, comes with a 16-ounce bottle of specially formulated Deep Cleansing Carpet and Upholstery detergent
  • Toe operated on/off switch
  • Can be used on carpets, bare floors and upholstery
  • US Warranty 1 year limited warranty on defects in materials and workmanship.
  • Extended US Warranty: Extended Warranty Available
  • Non-US Warranty: 30 days parts and labor
Specifications
Cord Length 20 Feet
Brush Speed Static Speed
Handle Standard Grip Handle
Available in CA Yes
Available in US Yes
Nozzle Type Rug / Floor Nozzle
Nozzle Width 11.25 Inches
Assembly Required Screw Driver
Clean Water Capacity OZ 133 Ounce(s)
Color Blue
Dirty Water Capacity OZ 128 Ounce(s)
Product (Hand) Weight LB 17.3 Pounds
Cleaning Solution Included Yes

Click HERE for Owners Manual for Hoover SteamVac H5810
No pickup at nozzle?

1. Clogged inlet screen
1. Remove Recovery Tank and check for debris on screen.
2. No suction at screened inlet
2. Check to insure that the handle is in the up position. This model is designed with a valve that shuts suction off when the handle is lowered all the way to the down position. The valve arm is actuated by the handle. Check for a stuck or broken valve. If this checks out, check the motor.
Suction at this inlet should measure approx. 55” of water.
3. Recovery Tank not seating against seal
3. Check to insure recovery tank is properly seated and is not warped or damaged.
4. Tool Door broken or missing
4. Check to insure that the Tool Door is closed and not damaged. Also check the condition of the seal.
5. Tubing clogged
5. Check for suction at tool door opening and again at the nozzle opening.
6. Recovery Duct missing or damaged
6. Lower Handle and check the duct that runs from the Hood back to the suction Hose.
7. Front Nozzle Plate missing or improperly
7. Check for damaged or missing Front Nozzle Plate. Properly assembled. assembly is outlined in the owner manual.
8. Front Nozzle Plate seal damaged
8. Check and replace if damaged.